Xenox C400
- Horizontal run: manual 210 mm; E-motion 175 mm
- Motorized Vertical run: 500 mm; 500 mm
- C-Arm LATERAL Rotation: ± 140° (± 180° *); + 180°; – 90° (-180° manual)
- C-Arm ORBITAL Movement: 150° (105°, -45°); 150° (105°, -45°)
- WIG-WAG: ± 10°; ± 10°
- Useful space: 810 mm; 810 mm
- C-Arm Depth: 640 mm; 640 mm
- Min/ Max Height: 1455 / 1955 mm; 1455 / 1955 mm
- Min/Max Length: 2085/ 2295 mm; 2110/ 2285 mm
- Max Width: 800 mm; 800 mm
- S.I.D.: 1065 mm; 1065 mm
*Measure obtained without security mechanical block
Xenox C300
- Horizontal run: manual 9″ 210 mm; E-Motion 9″ 175 mm; E-Motion 12″ 210 mm
- Motorized Vertical run: 500 mm; 500 mm; 460 mm
- C-Arm LATERAL Rotation: ± 140° (± 180° *); + 180° – 90° (-180° manuel); + 180° – 90° (-180° manual)
- C-Arm ORBITAL Movement: 135° (90°+45°); 135° (90°+45°); 115° (90°+25°)
- WIG-WAG: ± 10; ± 10°; ± 10°
- Useful space: 755mm; 755mm; 708mm
- C-Arm Depth: 665 mm; 665 mm; 640 mm
- Min/ Max Height: 1750 / 2250 mm; 1750 / 2250 mm; 1805/ 2265mm
- Min/Max Length: 2075/ 2285 mm; 2100/ 2275 mm; 2118/ 2293 mm
- Max Width: 800 mm; 800 mm; 800 mm
- I.D.: 1029 mm; 1029 mm; 1009mm
*Measure obtained without security mechanical block
OPERATING MODES AND FUNCTIONALITY
OPERATING MODALITIES OF (RTP) MEMORY
• CONTINUOUS FLUOROSCOPY
• HIGH DOSE PULSED FLUOROSCOPY
• PULSED FLUOROGRAPHY
• DIGITAL SNAPSHOT
• FLUOROSCOPY mA : (range: 0,5-8 mA)
• RADIOGRAPHY: 2 points technique (kV and mAs)
• CINE sequence: up to 25 fps. (included in basic configuration)
SOFTWARE BASE FUNTION (LIVE PROCESSING):
• Display of patient data, hospital name, x-ray parameters on operator monitor
• Recursive filter for noise reduction
• Dinamic Recursive Filter for patient’s movement compensation
• Edge enhancement spatial filter
• Edge enhancement spatial filter
• Horizontal and vertical image inversion
• Digital zoom during fluoroscopy mode (new)
• Metal detection in manual or automatic mode (new)
• Continuous digital image rotation
• Adjustable contrast and brightness
• Adaptive gamma curve
• Continuous fluoroscopy modality with LIH (Last Image Hold)
• Low dose fluoroscopy
• Timer Function
• MEASUREMENTS: length, angles, with manual calibration system, text overlay
• Anatomic program set up
• 80 anatomic programs in fluoroscope
POST-PROCESSING BASE FEATURES:
• Last Image Hold (LIH)
• Last fluoroscopy Run Hold (LRH)
• Horizontal/Vertical image inversion
• Digital image rotation
• Grey scale image inversion
• Adjustable contrast and brightness
• Adjustable Gamma curve (LUT)
• Edge enhancement
• Electronic shutters (Rectangular and circular)
• Electronic Zoom Roam from 1x to 5x
• Electronic mobile lens
• Mosaic Overview
• Patient’s selection for exams and images management
• Patient’s exams transfer in the DICOM system